Eaton Wiring Devices

Eaton Wiring Devices SGF15B GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Brown

MPN: SGF15B  •  SKU: 100075228  • UPC: 032664742279
Store SKU:  loading
Supplier SKU:  loading

loading

Promo Price:  loading

Volume Discounts
    How Would You Like to Get It?
    Store Pickup / Curbside
    Check in-store availability · Ready same day
    FREE
    Ship to Me
    Standard shipping · 5–7 business days
    FREE
    Local Delivery
    Same-day in Boulder · Order before 2pm
    $9.99
    Need Help Choosing? Our Green Vest experts can walk you through options or recommend a local pro.

    Eaton Wiring Devices SGF15B GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Brown

    Eaton Wiring Devices SGF15B

    Eaton's Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCIs provide state-of-the-art, dependable electrical shock protection. In addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power.

    Voltage Rating 125 V
    Current Rating 15 A
    Frequency Rating 60 Hz
    Number of Poles 2
    Number of Wires 3
    Wiring Type Back, Side
    Wire Size 14 to 10 AWG
    NEMA Configuration 5-15R
    Operating Temperature -35 to 66 deg C
    Mounting Type Wall
    Material Polypropylene
    Color Brown
    Dimensions 4.2 in L x 1.68 in W x 1.27 in D
    Includes Wallplate
    • Performs periodic self-tests to ensure integrity of GFCI protection
    • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
    • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
    • Ground termination with back wire clamp provides secure wiring and reduces installation time
    • Line side terminals are backed out and staked for fast installation
    • Horizontal test/reset button alignment provides larger unobstructed area
    • Test and reset buttons are color matched to provide great aesthetics
    • Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
    • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
    • Line-load miswiring protection
    • Tri-combo head terminal and mounting screws
    • Longer, wider strap provides 40% more contact area to wallboard
    • Rugged construction provides unsurpassed chemical and impact resistance